TCG140-4 is a 4G LTE universal IO module. It covers LTE Cat.1 communication with up to 5 Mbit upload. The device supports also 3G and 2G wireless communication and provides data connectivity on LTE-FDD, DC-HSDPA, HSPA+, HSDPA, HSUPA, WCDMA, EDGE, and GPRS networks. This makes it usable practically anywhere in the world where is available some kind of cellular coverage.
4G LTE universal IO module can work autonomously but it is specially optimized for M2M and IoT applications. The main option for M2M communication is HTTP API. The device supports HTTP and HTTPS Post with XML or JSON file.
The module offers a large number of analog inputs with 0 to 10 volts and a current loop – 0 to 20mA inputs. In addition, the device supports the MODBUS RTU interface for all compatible industrial devices, including all Teracom sensors.
The analog inputs with their standard ranges together with the MODBUS RTU interface make the integration of the unit into industrial applications very easy.
TCG140-4 is the successor to the popular TCG140. The two modules differ only in technology and communication ranges. The entire input-output peripherals and digital interfaces are 100% identical. This makes it easy to migrate from the 2G device to the 4G LTE module in places where 2G services are to be shut down.
The initial setup of the device is made through the graphical interface using a standard browser. On the field, the device can be set up remotely either with SMS or HTTP API commands. The FW update of the unit is possible over the air too.
4G LTE universal IO module utilizes robust metal box with accessories for DIN-Rail mounting.

*Προσοχή. Οι Ethernet Controllers της Teracom, δεν περιλαμβάνουν τροφοδοτικό στη συσκευασία τους και σε περίπτωση αγοράς, θα πρέπει να παραγγείλετε τροφοδοτικό χωριστά εάν δε διαθέτετε ήδη κάποιο συμβατό τροφοδοτικό.

Features:
• Multi-band connectivity
• Setup via USB, SMS or HTTP(S) API
• 2 digital "dry contact" inputs
• Up to 8 Teracom 1-Wire sensors support
• Up to 8 MODBUS RTU sensors/devices support
• 4 relay outputs with NO and NC contacts
• Up to 4 analog inputs with 0 to 10VDC range
• Up to 2 current loop (0-20mA) inputs
• HTTP(S) API commands
• Periodical HTTP/HTTPS Post with current status in XML or JSON
• Data logger for up to 70000 records
• Periodical HTTP/HTTPS Post with logger data in CSV format
• SMS alarm alerts (up to 5 numbers)
• Email alarm alerts (up to 5 email recipients), SMTP with TLS support
• DIN-rail mount ready
• Firmware update over USB or Internet

Applications:
• Data logging for drug and foods facilities
• Remote environmental sensing
• Smart remote facility management
• Remote monitoring of industrial processes
• Remote control of irrigation systems
• Smart cities street lighting control systems

Supported devices:
• Humidity and temperature sensor with MODBS RTU interface TSH300
• MODBUS RTU S0 pulse counter TDI340
• Precision temperature sensor with MODBUS RTU interface TST300
• Third party MODBS RTU sensors
• 1-Wire Pt100 transmitter TST200
• 1-Wire galvanic isolated AC/DC current sensor TSC200
• Galvanic isolated voltage sensor with 1-Wire interface TSV200
• 1-Wire galvanic isolated 0/20mA current loop transmitter TSA200
• Humidity and temperature sensor with 1-Wire interface TSH206
• Temperature sensor with 1-Wire interface TST103

Εγγυήσεις - Επιστροφές:
Επιστροφή Χρημάτων: Επισκευή - Αντικατάσταση:
20 ημέρες 36 μήνες
Specifications
Dimensions 158 x 119 x 34 mm
Operating temperature -20 to 55°C
Operating temperature for USB setup 0 to 40°C
Storage temperature -25 to 60°C
Ambient Relative Humidity 5 to 85% (non-condensing)
Memory Internal FLASH memory
Endurance 100 000 cycles (any save command or full scroll (70000 records) of the logger)
Standards and Certifications
Safety

EN 62368-1:2014+EN 62368-1:2014/AC1-3:2015+EN 62368-1:2014/A11:2017 + EN 62368-1:2014/AC:2017-03:2017,EN 62311:2008

EMC EN 55032: 2015 + EN 55032: 2015/AC:2016-07 + EN 55032: 2015/A11:2020 EN 55024: 2010 + EN 55024: 2010/A1:2015 EN 61000-3-2: 2014
RFU EN 61000-3-3: 2013 + EN 61000-3-3: 2013/A1:2019
EN 301 489-19 V2.1.1, EN 301511 V12.5.1, EN 301 908-1 V11.1.1, EN 301 908-13 V11.1.2, EN 301 908-2 V11.1.2, EN 303 413 V1.1.1
Green RoHS
Power supply
Operating voltage range (including -15/+20% according to IEC 62368-1) 10 to 28 VDC
Current consumption 0.37A @ 12VDC
Cellular interface
Standards LTE-FDD, DC-HSDPA, HSPA+, HSDPA, HSUPA, WCDMA, EDGE and GPRS
Bands 4G LTE: B1/B3/B7/B8/B20/B28
3G: B1/B8
2G: 900/1800MHz
SIM card size Micro
Antenna connector SMA-F
Analog inputs
Type Single-ended
Resolution 10 bits
Mode (Analog inputs 1 and 2) Voltage
Mode (Analog inputs 3 and 4) Voltage / Current (WEB interface selectable)
Input Range 0 to 10 VDC, 0 to 20 mA
Accuracy ±1%
Sampling Rate 500ms per channel (averaged value of 250 samples)
Input Impedance 1 mega-ohm (min.)
Built-in resistor for current mode 410 ohmsc
Digital inputs
Type Dry contact and logic level
Sampling rate 10ms
Digital filtering time period 30ms
Relay outputs*  
Type Form C (N.O. and N.C. contacts)
Contact current rating 3 A @ 24 VDC, 30 VAC (resistive load)
Initial insulation resistance 100 mega-ohms (min.) @ 500 VDC
Mechanical endurance 10 000 000 operations
Electrical endurance 100 000 operations @ 3 A resistive load
Contact resistance 50 milli-ohms max. (initial value)
Minimum pulse output 0.1 Hz at rated load
Digital sensor interfaces (1-Wire and RS-485)
Output voltage 5.0 ± 0.3 VDC
Maximum output current (for both interfaces) 0.2 A
Endurance  
Lithium battery
Type CR1220
Caution! Risk of explosion if the battery is replaced by an incorrect type.

* CAUTION: The device does not contain any internal overcurrent protection facilities on the relays’ contact lines. External fuses or short circuit current limiting circuit breakers, rated to 3 Amps, are to be used for overcurrent protection of the connecting lines.

Δεν υπάρχουν αξιολογήσεις για το προϊόν ακόμη.

ΣΧΕΤΙΚΑ ΠΡΟΪΟΝΤΑ

TERACOM_TST300.jpg
Teracom TST300 Precision temperature sensor
66,00 €
Άμεσα Διαθέσιμο
TST200.jpg
Teracom TST200 - 1-Wire Pt100 transmitter
95,00 €
Άμεσα Διαθέσιμο
TSH230.jpg
Teracom TSH330 - IP54 Modbus RTU temperature and humidity sensor
150,00 €
Άμεσα Διαθέσιμο
TSC200.jpg
Teracom TSC200 1-Wire current sensor
83,70 €
Άμεσα Διαθέσιμο
TSA200.jpg
TERACOM TSA200 0-20mA/4-20mA current loop sensor
51,00 €
Άμεσα Διαθέσιμο
TERACOM_TST103.jpg
Teracom TST103 - digital temperature sensor
37,00 €
Άμεσα Διαθέσιμο
GSPSU.jpg
Grandstream GSPSU12-12 Power supply 12V 1A
17,00 €
Άμεσα Διαθέσιμο
MikroTik_GM_1210.jpg
MikroTik Oem GM-1210 Power Adapter 12V 1A for RouterBOARD
6,20 €
Άμεσα Διαθέσιμο

ΕΙΔΑΤΕ ΠΡΟΣΦΑΤΑ

TCG140_4e.jpg
Teracom TCG140-4e 4G LTE universal IO module
250,00 €
Άμεσα Διαθέσιμο

ΑΤΟΚΕΣ ΔΟΣΕΙΣ ΜΕ ΠΙΣΤΩΤΙΚΗ
ΑΝΤΙΚΑΤΑΒΟΛΗ
ΤΡΑΠΕΖΙΚΗ ΚΑΤΑΘΕΣΗ
ΠΛΗΡΩΜΗ ΜΕΣΩ

ΣΥΝΔΕΣΗ ΧΡΗΣΤΗ